Skip to Main Content
  • Contact
Parameters Single-mode Multimode
APC MM
Low Loss Standard Low Loss Standard
Typical Insertion Loss (dB) 12-fiber 0.10 0.20 0.08 0.15
Max Insertion Loss (dB) 12-fiber 0.25 0.70 0.25 0.50
Typical Insertion Loss (dB) 24-fiber 0.15 0.25 0.15 0.20
Max Insertion Loss (dB) 24-fiber 0.35 1.00 0.35 0.50
Typical Insertion Loss (dB) 16-fiber 0.15 N/A 0.15 0.20
Max Insertion Loss (dB) 16-fiber 0.35 N/A 0.35 0.60
Typical Insertion Loss (dB) 32-fiber N/A N/A N/A 0.25
Max Insertion Loss (dB) 32-fiber N/A N/A N/A 0.60
Typical Return Loss (dB) ≥60 ≥25
Operating Temperature (°C) -40 to +75
Durability 500 mating cycles per TIA-568.3

Data Center

On Board Optics

Medical

Wireless

FTTH

Telecommunications

The MPO Plus connector can be used in temperatures as low as -40°C and up to 75°C.

The length of the MPO Mini is 37mm when using the 3mm short boot. Other length and size options are available.

Yes, you can add an optional pull tab to the connector.

Key features include gender change capability without opening the connector housing, low loss ferrules, and compliance with GR-1435 standards. It is also ISO certified and offers high durability with 500 mating cycles

It is ideal for high-density scenarios such as data centers, telecommunications, and enterprise networks where space is at a premium

For 12-fiber connectors, the typical insertion loss is 0.10 dB (single-mode) and 0.20 dB (multimode), with maximum insertion losses of 0.25 dB and 0.70 dB respectively

Yes, it operates effectively in temperatures ranging from -40°C to +75°C

Yes, it is available in 12, 16, 24, and 32 fiber versions

The connector is designed to withstand 500 mating cycles as per TIA-568.3 standards

Yes, it supports both single-mode and multimode applications with low loss ferrules

Yes, it allows for polarity change without the need for tools or opening the housing

The connector complies with GR-1435 standards and is ISO certified.