Skip to Main Content
  • Contact
Parameters Single-mode
APC
Standard
Typical Insertion Loss (dB)1 0.10
Max Insertion Loss (dB) 0.20
Operating Temperature (°C) – 40 to +75
Durability 50 matings
IP-Rating2 IP68

1 Based on Master Grade jumper to Low Loss random mating test.

2 The IP rating was validated using a SENKO sourced cable and procedure. It is recommended to retest IP rating for any other cable types.

RoHS-logo
REACH logo

The first digit represents the level of protection against solid bodies such as dust, and the second digit does the degree of protection against water. For example, IP68 means no ingress of dust, no water ingress >1m, >30mins.

Currently IP-Solid SC connector supports 3.0 or 5.0mm OD round cable.

No special tool is required for the installation of IP-Solid connector.